Contrast

Infrared sauna: what the studies tested, and how to log it

Infrared cabins generally run at 45 to 60 °C, against 80 to 100 °C for a Finnish sauna. The Finnish cohort studies used saunas at about 79 °C and their authors caution against applying the results to infrared. A 2018 review found 25 infrared studies, all at 60 °C, mostly small. Contrast logs infrared as a sauna round and compares it only at a similar air temperature.

Most of what gets said about sauna and health comes from studies of hot, traditional Finnish saunas. Infrared cabins are a different machine, run at a different temperature, and the research on them is a different body of work. Keeping those apart is most of the job, in reading the studies and in keeping a log.

How the two differ

A Finnish sauna heats the air. A 2018 systematic review describes the usual practice as short exposures of 5 to 20 minutes at 80 to 100 °C, in dry air with bursts of humidity from water thrown on the stones.

An infrared cabin heats the body more directly with infrared emitters. The same review describes these cabins as running without water or added humidity, and generally at lower temperatures, 45 to 60 °C, for similar lengths of time.

Finnish saunaInfrared cabin
Air temperature (per the 2018 review)80–100 °CGenerally 45–60 °C
HumidityDry, with bursts from water on the stonesDry, none added
Where it is usually foundFamily, group and public settingsMore often built and sold for one person

Temperature labels on a control panel are not always the temperature at your head, and both kinds vary from one installation to the next. A thermometer at head height on the bench you use settles it.

What the Finnish cohorts did not study

The Finnish studies that carry most sauna claims followed 2,315 middle-aged men for a median of 20.7 years. Their saunas ran at about 79 °C. Against once a week, four to seven sessions a week was associated with a hazard ratio of 0.37 for sudden cardiac death in that cohort.

The authors explicitly caution against applying the results to infrared cabins, steam rooms or cooler saunas. The cohorts are observational, habits were asked about once at the start, and the proposed mechanism runs through the cardiovascular load of high heat. A cabin at 50 °C is a smaller load, and nobody has measured how much of the Finnish association would survive the change.

What the infrared studies were

The 2018 review gathered 40 clinical studies of repeated dry sauna, with 3,855 participants in total. Eleven used Finnish saunas, 25 used infrared, and four used other dry saunas.

Three features of that evidence matter more than any single finding:

  • Every infrared study ran at 60 °C, for 15 to 30 minutes, which is the top of the range the review gives for cabins in general.
  • Most studies were small. Most enrolled fewer than 40 people, and only 13 of the 40 were randomised controlled trials.
  • Many enrolled people with specific diagnoses, and the heart studies were mostly in hospital patients, so the people studied are far from a typical person using a gym’s cabin.

The review’s own conclusion was that there is not yet enough evidence to tell apart any particular health differences between repeated Finnish and repeated infrared sauna bathing. That is a statement about the size of the evidence, and it cuts both ways: it does not show that infrared matches Finnish sauna, and it does not show that it falls short.

How Contrast logs an infrared session

Contrast has four modalities and no more: sauna, bath, plunge and shower. An infrared session is a sauna round, picked by hand on the watch or logged on the iPhone, because no watch sensor can detect dry heat of either kind.

What keeps infrared and Finnish rounds from being treated as one thing is the air temperature you enter for the sauna, either when logging by hand or under Edit session. Two measures use it:

Heat strain compares your heart rate five minutes into your first heat round, above that day’s resting heart rate, and only against saunas within 10 °C of the air temperature you entered, or all together if you entered none. Heat strain is rated borrowed: the research behind it is mostly on exercise in the heat, where heart rate under the same heat falls within the first week, and the effect of passive heat alone is smaller and less certain. A 50 °C cabin and an 85 °C sauna are never set against each other once the temperatures are in.

Sauna sessions counts days with at least five minutes of sauna over the last four weeks and places you in the Finnish study’s frequency and length groups. It counts infrared minutes the same as Finnish ones. The metric page says what this post says: the groups come from men using saunas at about 79 °C, and the authors caution against infrared. For an infrared user, the placement describes how often you go, and the cohort’s outcomes do not travel with it.

Humidity, the variable nobody types in

Air temperature is not the only difference. In a Finnish study at 80 °C, heart rate rose about 60% in dry air and about 130% once the air was made humid.

Infrared cabins add no humidity, while a Finnish sauna changes with every ladle of water. That is part of why Contrast only compares sauna rounds with each other at a similar air temperature rather than with baths, and why a heat strain reading from a steamy Saturday session can sit well above a dry Tuesday one at the same dial setting. The app does not record humidity, so it cannot separate the two; the honest response is to read the trend over several sessions rather than any one.

The watch in the cabin

Heart rate in any sauna needs the watch on your wrist, and Apple’s guidance limits that. Apple advises against wearing any Apple Watch model other than Ultra in a sauna, and against wearing Ultra in a sauna above 55 °C (130 °F).

An infrared cabin is the one kind of sauna where an Ultra may fall inside that limit, and the 60 °C used in every study in the review would not. So unless the watch is an Ultra and the cabin runs at 55 °C or below, the round is timed with the watch left outside and has no heart rate, which also means no heat strain or heart work for that round. The watch shows Apple’s guidance the first time a sauna round starts, and keeps timing with the watch off.

Safety

The most cited review of sauna risk concludes that sauna is well tolerated by most healthy adults, and names unstable angina, recent heart attack and severe aortic stenosis as reasons to avoid it. Alcohol raises the risk of low blood pressure and arrhythmia in the heat. A cooler cabin does not change that list. Check with a doctor first with a heart condition, high or low blood pressure, or during pregnancy.

Common questions

How hot is an infrared sauna?

A 2018 systematic review describes infrared cabins as generally running at 45 to 60 °C, against 80 to 100 °C for a Finnish sauna. Cabins vary, so a thermometer at head height says more than the control panel.

Do the Finnish sauna studies apply to infrared?

Their authors caution against it. The cohort used traditional saunas at about 79 °C, and the authors advise against applying the results to infrared, steam or cooler saunas.

Can I wear an Apple Watch in an infrared sauna?

Apple advises against wearing any model other than Apple Watch Ultra in a sauna, and against wearing Ultra in a sauna above 55 °C (130 °F). An infrared cabin may be below or above that, so it depends on the cabin.

Does Contrast have an infrared mode?

No. An infrared session is a sauna round. Entering the cabin's air temperature is what keeps it from being compared with a much hotter Finnish sauna.

Sources